Applies to AMT12, all models Overview Error codes 70 thru 79 overview, see 70-79 Overview. Issue symptom The AMT12 flat belt system has a predetermined life span of 100,000,000 (100M) strides. The AMT12 maintains a stride count independent from the overall machine stride count. When this stride count reaches 90,000,000 (90M) strides, Error 78 is recorded in the error log and ...
read moreApplies to Error "ERR" codes: AMT12 series Warning "WRN" codes: SCL800 series Overview Error codes 70 thru 79 overview, see 70-79 Overview. Issues symptoms The UPCA and LPCA compare the stride count record written on each EEPROM. Error 74: The LPCA stride count is less than the UPCA’s, and the UPCA is less than 30,000 strides. Error 75: The LPCA stride ...
read moreApplies to Error "ERR" codes: AMT12 series Warning "WRN" codes:: SCL800 series Overview Error codes 70 thru 79 overview, see 70-79 Overview. Issues symptoms When power is applied to the UPCA and LPCA, the stride count written on each of the EEPROMs will be compared to each other and to a set of preset stride conditions. If the stride count written on the EEPROM's do not...
read moreAMT12 Flat Belt and SCL800 Drive Belt Error and Warning Codes Overview Applies to AMT12 and SCL800 machines Issue symptoms The AMT12 flat belt and SCL800 drive belt integrity (not breaking) is critical to exerciser safety and must be replaced at the specified usage stride or step count. These codes are used to monitor the AMT12 flat belt stride count and the SCL800 drive belt step count ...
read moreApplies to EFX16 ellipticals Issue symptoms Error 69 is shown after pressing QuickStart. The unit may not be able to power OFF in this situation, which can lead to battery failure or depletion. A primary symptom would be a console that does not power OFF, or a console that will not work when pedaling is stopped (indicating battery failure). Troubleshooting steps: Note: This ...
read moreApplies to Chrono bikes Issue symptoms The GEM module affecting ANT+(Pronounced ant plus is a wireless protocol for monitoring sensor data such as a person's heart rate or a bicycle's tire pressure) and Bluetooth® data transport has not always responded to control queries. This is considered a non-fatal condition as sporadic errors have been detected during testing, but Bluetooth ...
read moreApplies to EFX16 ellipticals, Chrono bikes Issue symptoms Error 65 Error 65 will show at startup. It indicates that the software in LPCA(Lower Printed Circuit Assembly Board) is not compatible with the software in the UPCA(Upper PCA Board). It could be caused by a wrong version of the LPCA being installed and may be resolved by a software update. Workouts will not run at all if ...
read moreApplies to Chrono(Spinner Chrono Power bike) bike Issue symptoms Generator voltage is or has been detected as too high. The error is only detected or cleared while pedaling above 35 RPM. May be a temporary condition due to some rider pedaling modalities. Troubleshooting steps Run the Generator Voltage and Amp service tests to verify that there is real-time voltage and current while ...
read moreApplies to Chrono(Spinner Chrono Power bike) bike Issue symptoms Generator voltage is or has been detected as too low (Error 57) or too high (Error 58). These errors are only detected or cleared while pedaling above 35 RPM. May be a temporary condition due to some rider pedaling modalities. Troubleshooting steps Run the Generator Voltage service test to verify that there is ...
read moreApplies to Chrono(Spinner Chrono Power Bike) Issue symptoms RPM is or has been detected as too high. The RPM is measured from one of the three, time-varying AC(Alternating Current) phases from the generator (pin 3). May be a temporary condition due to some rider pedaling modalities. Troubleshooting steps Use the RPM service test to measure the real-time RPM while ...
read more