Precor Error code 09 Troubleshooting Lower PCA Memory Test Errors

Dec 26, 2021

Precor Error code 09 Troubleshooting Applies to All cardio equipment

During the power-up test sequence, the lower PCA memory locations are checked. Error 09 indicates a fault was found, which, when it is consistently displayed, is often a lower PCA problem. Failures causing this error message to be displayed are rare.

These messages may display intermittently due to external causes. If the unit's AC input significantly dips during the power-up test sequence, the test could fail and trigger one of these errors. In addition, treadmills operating on non-dedicated AC circuits may see these errors intermittently.

Troubleshooting steps

Reproduce the error and evaluate.

  1. Switch OFF unit.
  2. Switch ON unit. Repeat.
  3. If the error message is consistently displayed when the unit is powered up, replace the lower PCA.