Applies to Treadmills, self-powered units with external AC, and Chrono bikes
Issue symptoms
This watchdog program monitors the voltage of the upper PCA and displays error 11 if it drops below the acceptable value. This can be present if the communications cable between the lower PCA and the upper PCA is faulty, or if a failure in the upper PCA causes an overload in the low voltage power supply, causing it to drop below the limit.
It is also possible to see this message displayed intermittently due to external causes. Error 11 appears if the unit's AC input significantly dips during the power-up test sequence. Treadmills operating on non-dedicated AC circuits may see this message displayed intermittently.
Troubleshooting steps
Issue symptoms
An internal processor failed and so the console may work properly.
Troubleshooting steps
If this error is present and comes back after clearing, replace the console.