Precor Error Code 39 LPCA ASL processor communication Error/Warning
Mar 03, 2022
Applies to
EFX800-16. EFX700-17 ellipticals: Error 39:
SCL800: Warning 39:
Issue symptoms
There is a loss of communication between the Major and ASL processors on the LPCA board. An error/warning 39 event will be logged but an error/warning message will not be shown on the console. Depending on the failure mode, the ASL status light may not illuminate.
Possible causes
- Damage to one of two processors on the LPCA board: either the Major or ASL processors.
- Intermittent failure caused by a shorted ASL cable or a short on the ASL board.
Troubleshooting steps
Case 1: Error/Warning 39 only occurs intermittently, not at every power up.
- Replace the ASL board and ASL cable.
- If issue continues, replace the LPCA board.
Case 2: Error/Warning 39 occurs continuously and can be reproduced at every power up.
- Disconnect the ASL cable from the ASL board. Wait for diagnostic LEDs on the LPCA to power OFF, then power ON the machine and verify if Error/Warning 39 reoccurs.
- If Error/Warning 39 does not reoccur, replace the ASL board.
- Disconnect the ASL cable from the LPCA board. Wait for diagnostic LEDs on the LPCA to power OFF, then power ON the machine and verify if Error/Warning 39 reoccurs.
- If Error/Warning 39 does not reoccur, replace the ASL cable and the ASL board.
- If Error/Warning 39 does reoccur, replace the LPCA board, the ASL board, and the ASL cable.