Issue symptoms

Generator voltage is or has been detected as too high. The error is only detected or cleared while pedaling above 35 RPM. May be a temporary condition due to some rider pedaling modalities.

Troubleshooting steps

  1. Run the Generator Voltage and Amp service tests to verify that there is real-time voltage and current while pedaling. While pedaling at 60 RPM, the generator voltage should read approximately 9 VAC(Voltage in an alternating current circuit) and the generator amperage should read 0.40 amps.

Note:  If the external charger is connected, the voltage will always be shown as the charger’s voltage (approximately).

  1. While pedaling, the voltage should vary based on the RPM (higher RPM = higher voltage). The current should go lower as the voltage/RPM increases. If it’s always the same or high, the likely cause is the LPCA(Lower Printed Circuit Assembly Board).
  2. If the Generator Current varies, the system may have a battery problem (run Battery Service tests).
  3. If the battery checks GOOD, double-check all wiring and connections.
  4. If conditions persist, swap the LPCA, then the console.